Starting a Business

Opening a Restaurant in a Conservation Shophouse in Singapore

What conservation status means for an F&B fit-out, which approvals you need from URA and other agencies, and what to check before you sign a shophouse lease.

Colourful conservation shophouses in Singapore

Key takeaways

  • URA says Conservation Permission is required before any works to a conserved building, and before a new use starts.
  • URA’s guidelines follow the “3R” principle: maximum Retention, sensitive Restoration and careful Repair. Roof tiles, timber floors, party walls and front facade elements are protected.
  • New eating houses are not allowed in some conservation areas, including Kampong Glam and parts of Little India, Blair Plain and Chinatown. Check before you sign.
  • A restaurant application in a conservation area needs a menu, operating hours, a layout plan, a Letter of Undertaking and gas details. URA’s fee is $500, with about 10 working days to process.
  • Kitchen flues must meet both NEA’s exhaust rules and URA’s conservation guidelines. Keep back lanes clear, as SLA asks.

This guide is general information, not legal or professional advice. URA, SLA, NEA, SCDF and BCA rules quoted were checked on official pages in September 2026 and can change. Guidelines differ between conservation areas and individual buildings. Check with URA and a qualified person (QP) before you sign a lease or start any work.

A conserved shophouse gives a restaurant character that a mall unit cannot match: high ceilings, timber floors, a five-foot way and a facade guests photograph. For signs on the front, see our guide to shop sign approvals in Singapore. It also comes with rules that do not apply to newer buildings. This guide explains what conservation status means for an F&B fit-out, which approvals you need, and how to check a unit before you commit. For the general opening steps, start with how to open a restaurant in Singapore. Planning a heritage concept such as Nyonya food? See how to open a Peranakan restaurant.

What conservation status means for your unit

URA’s conservation areas page groups conserved buildings into Historic Districts (Boat Quay, Chinatown, Kampong Glam and Little India), Residential Historic Districts (Blair Plain, Cairnhill and Emerald Hill), Secondary Settlements and bungalows. URA says the extent of conservation and adaptation varies by area and building. Its conservation guidelines cover planning parameters, restoration guidelines, envelope control, signage and use, and state that “Conservation Permission is required before all additions & alteration works and operations of new use can begin.”

URA’s Historic Districts guidelines are built on the “3R” principle: “maximum Retention, sensitive Restoration and careful Repair”. For a restaurant, the elements that most often affect the design are:

  • Roof. Traditional small, V-profile, unglazed, natural-colour clay roof tiles are to be used, and the original pitch and profile kept.
  • Timber floors. “The timber floor should be retained.” New structural supports should abut the party walls.
  • Party walls. The first 3m of the load-bearing party wall behind the first-storey shopfront is to be retained, and openings are limited.
  • Front facade. Original windows, doors and fanlights are retained, and coloured glass “cannot be replaced with clear glass”.
  • Airwells. No structure, lift or floor can be added within the airwell space; only lightweight transparent or translucent roofs.
  • Services. Air-conditioning condensers are to be integrated within the building or screened, and other utility or conduit pipes may not be surface-mounted on external walls. Exhaust fans go at the rear facing courtyards, and flues are neatly located at roof slopes or rear facades.

These are Historic District rules. Residential Historic Districts and Secondary Settlements have their own guidelines, and URA offers an e-service to apply for Specific Restoration Guidelines for a particular building. Ask for these early; they shape the kitchen layout.

Conservation Permission: which works need it and who submits

URA’s additions and alterations page says: “Any works to conserved buildings require Conservation Permission prior to the start of works.” It divides works into categories:

Category What it covers Who submits Fee and time
Category 1 (A&A) Works with significant impact on key elements, such as a new rear extension A QP who is a Registered Architect Fee depends on the works; see URA’s fee schedule
Category 2 (A&A) Works with some impact on key elements A Registered Architect or Professional Engineer Fee depends on the works
Category 3 Minimal, localised works or repair and maintenance, including adding or repositioning a flue, and adding or repositioning air-conditioning units and screening Owners or contractors; no QP needed Free of charge; about two weeks

Your designer should confirm the category of every item before tender. For costs and layout, see our restaurant interior design guide. A kitchen fit-out often mixes all three: a new rear extension (Category 1), internal changes and a flue (Category 3). Separate approvals from SFA, SCDF, NEA and PUB still apply on top of Conservation Permission; our renovation checklist lists them.

Change of use to a restaurant in a conserved shophouse

A lease does not make a shophouse legal for F&B. Check the approved use for the specific floor on URA SPACE, and if it is not already approved as a restaurant, apply for a change of use.

URA’s use of buildings in conservation areas page sets out the key restrictions:

  • Problematic Traffic Areas. “New eating houses and expansion of existing eating houses are not allowed” in the Kampong Glam Conservation Area, Serangoon Road and Jalan Besar within the Little India Conservation Area, and Kampong Bahru Road, Spottiswoode Park Road, Blair Road and Neil Road within the Blair Plain Conservation Area.
  • Chinatown. “New eating houses are not allowed at Ann Siang Hill / Ann Siang Road / Erskine Road / Club Street / Gemmill Lane within the Chinatown Conservation Area.”
  • First storey. In Historic District core areas, “The first storey in the core area has to be for activity-generating uses such as shops.”

More broadly, URA’s criteria for restaurant use also list locations where new eating houses are unlikely to be approved, including Balestier Road, East Coast Road and Joo Chiat Road. URA says proposals in commercial or mixed developments in those areas can be considered if the building has its own car park lots available for public use. The same page explains how URA tells a restaurant from a bar or pub: a kitchen, food available until a reasonable time before closing, adequate indoor dining space, and marketing and decor that do not present the premises as mainly a place for drinking. If your concept is closer to a bar, read our bar guide.

For a restaurant application in a conservation area, URA asks for:

  • the business concept, including a complete food and beverage menu and operating hours
  • a detailed layout plan clearly marking the kitchen and dining areas, with tables and chairs shown
  • a Letter of Undertaking
  • gas details: piped gas is encouraged; cylinder gas must be kept within the property boundary, and LPG cylinders need a plan of the cabinet and an SCDF Notice of Approval
  • a kitchen flue that complies with conservation guidelines and is “painted the same colour as the background wall”

URA’s change of use page gives the processing fee as $500, with about 10 working days to process. Make your lease conditional on approval if it is not yet in place.

Kitchen exhaust, flues and M&E

Exhaust is usually the hardest part of a shophouse kitchen, because you are working with a pitched clay-tile roof, neighbours close by and conservation rules on flue position. If smoke or smell complaints arise, see dealing with neighbours as an F&B operator.

NEA’s Code of Practice on Environmental Health (2025 edition) says kitchen fumes “shall be exhausted above the roof”. Where that is not practical, the discharge point may be at another outdoor location that does not face adjacent buildings. Outlets must be more than 5m from cooling towers. The code also asks for a suitable aesthetic screen to hide the exhaust duct and outlets from neighbours and the public, particularly near homes, and it requires fumes to be treated by an air cleaning system with no visible smoke. The hood and duct must be degreased by a specialist at least once every 12 months, with records kept.

Combine that with URA’s guidelines: flues at roof slopes or rear facades, exhaust fans at the rear facing courtyards, and the flue painted to match the wall. In practice:

  • Route the duct up the rear of the building, not the front facade.
  • Choose menu and equipment with exhaust in mind. Heavy wok and charcoal cooking needs more extraction and air cleaning than a café.
  • Plan the condenser location with the landlord, integrated or screened as URA requires.
  • Plan the grease trap early. PUB’s grease trap page says all food establishments need one, with NEA and PUB approval before installation.

Fire safety and upper floors

Fire safety works need plans submitted by a qualified person and approved by SCDF (see SCDF’s plan approval page). Older shophouses can make this harder: narrow staircases, timber floors and a single entrance all need attention.

  • Occupant load. SCDF’s Fire Code Table 1.4B lists 1.5m² per person for a restaurant and 1m² per person for a bar or pub. The figure sizes exits; it is not a seating target.
  • Exits. Under clause 2.2, an exit door needs a clear width of at least 850mm, and a room needs two exits remote from each other once its occupant load exceeds the maximum for one door; Table 2.2.10 lists 50 for assembly occupancies. Your QP determines what applies.
  • Upper floors. Approved use is set floor by floor, so a restaurant on the second storey needs its own approval. URA’s conservation use guidelines encourage upper storeys to be used for residential or institutional purposes, and at some Club Street and Gemmill Lane addresses allow only office use if the upper storeys are commercial. Check the specific address.
  • Gas cylinders. If piped gas is not available, the LPG cabinet needs SCDF approval, as noted above.

Our floor plan guide explains occupant load, exits and accessible tables in more detail.

Signage on a conserved shophouse

URA’s signage guidelines for conservation areas set where signs can go:

  • Five-foot way: signs can hang between the column and the party wall, with at least 2,500mm headroom beneath.
  • First-storey column: a projecting sign no wider than 600mm, with brackets no wider than 200mm. It goes on the left side of the building and cannot project beyond the roadside drain.
  • Frieze: individual letters or a sign panel can be mounted within or suspended from the frieze.
  • Lighting: traditional signs are non-illuminated carved timber; contemporary signs can be lit from within their casings.

URA says all signage proposals in conservation areas are submitted to the Advertisement Licensing Section of BCA, or cleared first through URA’s Category 3 e-service. BCA’s signboard licence page says a single sign or a related series of not more than 5m² in total is exempt, and complete applications typically take about 7 working days. Confirm the design with your signage contractor before fabrication.

Back lanes, five-foot ways and outdoor seating

Many shophouse restaurants use the back lane for deliveries and refuse, and want tables on the five-foot way. Both are controlled.

  • Back lanes. SLA’s State land guidance says: “Do not store or place items on State land, especially in back lanes so as not to obstruct area cleaning and emergency rescue efforts”, and “Do not fence up State land back lanes”. Keep bins, gas cylinders, crates and chillers inside your boundary.
  • Outdoor activity. SLA says businesses must confine their activities, including sitting and display areas, within their premises. To use State land, you need URA planning permission first, then a Temporary Occupation Licence (TOL) from SLA.
  • Outdoor refreshment areas. URA’s development control handbook says ORAs are included as gross floor area, with bonus GFA only under specific schemes.
  • Five-foot way. URA’s restoration guidelines ask for non-slip finishes and ramps no steeper than 1:10 where levels change. Keep it clear for pedestrians unless you have approval.

Plan storage inside the unit from day one. A shophouse kitchen without a bin point and dry store will push things into the lane.

Surveying the unit before you sign

Bring your contractor, and ideally your QP, to the viewing. Check:

  • Conservation and use: which conservation area and guidelines apply, the approved use per floor, and whether the street is on URA’s restricted list.
  • Structure: timber floor and beam condition, termite damage, roof leaks and damp in party walls. Repairs must follow the 3R principle, so budget for them.
  • Exhaust route: an existing approved flue, or a realistic route up the rear.
  • Power: the electrical capacity against your equipment list.
  • Gas: piped gas availability, or space for an approved LPG cabinet within the boundary.
  • Grease trap and drainage: an existing trap, its size, and who maintains it.
  • Network and mobile signal: thick walls and long, narrow floor plates can leave dead spots. Test signal at the back of the unit and upstairs.

That last point matters for your systems. ChaChaCha’s restaurant POS keeps taking orders if the internet drops and syncs later. In a long shophouse, QR ordering lets guests scan, order and pay from the table without waiting for a server to walk the length of the room, and a kitchen display system with station routing sends orders to an upstairs or rear kitchen. Plan wired network points before walls are closed.

Leasing a shophouse

Shophouses are usually privately owned, so terms vary. The Code of Conduct for Leasing of Retail Premises lists shophouses and shop flats among the locations it covers, for qualifying leases of one year or more signed on or after 1 February 2024. It caps the security deposit at 3 months’ gross rent for units up to 5,000 sq ft on leases of up to 3 years, as a general rule. IRAS’s stamp duty page says duty for a lease of 4 years or less is 0.4% of the total rent, and documents signed in Singapore must be stamped within 14 days.

Shophouse-specific points to negotiate:

  • Make the lease conditional on URA change of use and Conservation Permission.
  • Agree who pays for structural and roof repairs that conservation rules require.
  • Define reinstatement carefully. Some works, such as an approved flue, may be better left for the next tenant.
  • Get the landlord’s consent for the exhaust route and condenser position in writing.

Our F&B lease guide covers the Code and stamp duty in full.

Timeline and checklist

Durations depend on the unit and the works. Official timings below come from the agencies named; items marked “varies” depend on your QP and the scope.

Step What happens Official timing or fee
1. Due diligence Check conservation area, restricted streets, approved use per floor, structure, exhaust, power, gas, grease trap Before signing
2. Lease Conditional on approvals; stamp duty paid Stamp within 14 days of signing (IRAS)
3. Change of use URA application with menu, hours, layout, Letter of Undertaking, gas details $500; about 10 working days (URA)
4. Conservation Permission Category 1 or 2 by QP; Category 3 by owner or contractor Category 3 free, about two weeks; A&A varies
5. SFA licence layout Food Shop Licence application with layout plan 7 working days for complete applications (SFA)
6. SCDF, NEA and PUB Fire safety plans, exhaust design, grease trap approval via QP and contractor Varies
7. Signage URA guidelines; BCA licence unless exempt About 7 working days (BCA)
8. Build and install Restoration, kitchen, flue, M&E, POS, KDS and network Varies
9. Inspect and open SFA pre-licensing inspection, then soft launch After works

Before you sign, tick off:

  1. Street is not on URA’s restricted list for new eating houses.
  2. Approved use confirmed for each floor you plan to use.
  3. Specific Restoration Guidelines requested for the building.
  4. Exhaust route agreed that satisfies both NEA and URA.
  5. Gas, power, grease trap and structure checked by your contractor.
  6. Sign locations and sizes fit URA’s guidelines.
  7. Back-of-house storage planned inside the unit.
  8. Lease conditional on approvals, with repair and reinstatement terms agreed.

Check each point with URA and a qualified person, because the guidelines for your building may differ from the general rules above. When you are ready to plan POS, kitchen screens and QR codes for a narrow, multi-level unit, talk to us. Pricing is quote-based, and our grant guide explains EDGE Grant support.

Web Admin

Written by Web Admin

Frequently asked questions

Can I open a restaurant in any conserved shophouse?

No. URA does not allow new eating houses in some conservation areas, including Kampong Glam, Serangoon Road and Jalan Besar in Little India, parts of Blair Plain, and Ann Siang Hill, Club Street and nearby streets in Chinatown. Elsewhere, URA assesses change of use applications case by case. Check the address with URA before you sign a lease.

What is Conservation Permission?

It is URA's approval for works to a conserved building or for a new use. URA says any works to conserved buildings need Conservation Permission before they start. Major works must be submitted by a Registered Architect or Professional Engineer, while minor Category 3 works, such as repositioning a flue, can be submitted by owners or contractors free of charge.

Where can the kitchen exhaust go in a shophouse?

NEA's Code of Practice says kitchen fumes should be exhausted above the roof, or at another outdoor point not facing adjacent buildings where that is not practical, after treatment with no visible smoke. URA's guidelines place flues at roof slopes or rear facades, painted to match the wall. Your qualified person designs a route that meets both.

Can I put tables in the back lane or on the five-foot way?

Not without approval. SLA says businesses must keep activities, including seating and displays, within their premises, and must not store items in State land back lanes. Using State land needs URA planning permission and then an SLA Temporary Occupation Licence. Outdoor refreshment areas also count as gross floor area under URA's rules.

What signs are allowed on a conserved shophouse?

URA allows signs hung in the five-foot way with at least 2,500mm headroom, a projecting column sign up to 600mm wide on the left side, and letters or panels on the frieze. Contemporary signs can be lit from within. Proposals go to BCA's Advertisement Licensing Section, and small signs totalling 5 square metres or less are exempt from licensing.

How long does it take to get approvals for a shophouse restaurant?

URA's change of use takes about 10 working days with a $500 fee. Category 3 conservation works take about two weeks and are free. SFA reviews a complete Food Shop Licence application within 7 working days, and BCA signage about 7 working days. Larger conservation works and SCDF plans vary, so ask your qualified person.

How much does it cost to rent a shophouse for a restaurant?

Shophouse rents are set privately by each owner, so there is no standard rate. Compare units on rent per square foot per month for the floors you will actually use, then add service charges, the security deposit, stamp duty (0.4% of total rent for leases of four years or less) and the cost of repairs the landlord expects you to cover. A unit already approved for restaurant use with a working flue can be worth a higher rent.

Why does renovating a conserved shophouse cost more?

Because more of the building must be kept and repaired rather than replaced. URA's 3R principle protects roof tiles, timber floors, party walls and the front facade, so structural repairs, termite treatment and damp proofing often appear once work starts. Routing the exhaust up the rear, screening condensers and using a qualified person for Category 1 or 2 works add further cost. Budget a generous contingency and survey the unit before signing.

Can a shophouse restaurant serve alcohol late at night?

It depends on the approved use and the liquor licence. A Class 1A licence allows supply until 11.59pm, but SPF says it will not grant extended hours to premises approved only as a restaurant. A "restaurant and bar" use can apply for extensions, except in areas shaded on SPF's map. Check the use approval with URA and the licence class with SPF before you plan a late-night menu or sign a lease.

Can I have live music in a shophouse restaurant?

Live music needs a public entertainment licence from SPF, which is separate from the liquor licence. URA's definition of a restaurant also excludes live music or live entertainment, so you may need a different approved use. SPF lists locations, including the Historic Conservation Areas, where new public entertainment licences are unlikely. Check both approvals before signing, and plan for neighbours living above or behind the unit.

See ChaChaCha running in your business